๐Ÿ“ž +91-7667918914 | โœ‰๏ธ ijireeice@gmail.com
International Journal of Innovative Research in Electrical, Electronics, Instrumentation and Control Engineering
International Journal of Innovative Research in Electrical, Electronics, Instrumentation and Control Engineering A monthly Peer-reviewed & Refereed journal
ISSN Online 2321-2004ISSN Print 2321-5526Since 2013
IJIREEICE meets the suggestive parameters outlined in the latest University Grants Commission (UGC) for peer-reviewed journals, ensuring high standards of research integrity, publication ethics, and academic excellence.
← Back to VOLUME 4, ISSUE 11, NOVEMBER 2016

Classification of PPG Arrhythmias using Discrete Wavelet Feature Extraction and Artificial Neural Networks

Jayadevappa B.M, Mallikarjun S. Holi

๐Ÿ‘ 1 view๐Ÿ“ฅ 0 downloads
Share: ๐• f in โœˆ โœ‰
Abstract: PPG signal is an effective method to assess the cardiovascular parameters like heart rate, blood oxygen saturation, blood pressure and respiration rate. Motion and other artifacts introduced during acquisition of PPG, limits the accuracy in estimation of clinical parameters. In this paper, we present wavelet based feature extraction and motion artifacts removal methodology to overcome the issues of heart and respiratory parameter estimation. In the proposed algorithm, point of interest coefficients are ascertained for every wavelet sub-band grid, producing a changed wavelet sub-band network. This makes the exhibited algorithm more efficient. Every information set comprises of deliberately made conceivable MA noises, viz., vertical, flat, waving, and squeezing MAs with distinctive breathing examples. The technique is connected on the recordings accessible of Physionet dataset. The measurable and classification investigation, performed to test the viability of the introduced new algorithm, uncovered a decent acknowledgment for inferred respiratory signal, when contrasted and the initially recorded respiratory signals utilizing traditional strategy. To perform the classification of the dataset, neural network is used. The proposed strategy obviously outperforms the customary heart rate detection system in the vicinity of MA. The results of proposed system show the approximate 99.9% of sensitivity and 99.7% of specificity.

Keywords: PPG, Heart rate, Respiration rate, classification, neural network.

How to Cite:

[1] Jayadevappa B.M, Mallikarjun S. Holi, โ€œClassification of PPG Arrhythmias using Discrete Wavelet Feature Extraction and Artificial Neural Networks,โ€ International Journal of Innovative Research in Electrical, Electronics, Instrumentation and Control Engineering (IJIREEICE), DOI: 10.17148/IJIREEICE.2016.41126

Creative Commons License This work is licensed under a Creative Commons Attribution 4.0 International License.