πŸ“ž +91-7667918914 | βœ‰οΈ ijireeice@gmail.com
International Journal of Innovative Research in Electrical, Electronics, Instrumentation and Control Engineering
International Journal of Innovative Research in Electrical, Electronics, Instrumentation and Control Engineering A monthly Peer-reviewed & Refereed journal
ISSN Online 2321-2004ISSN Print 2321-5526Since 2013
IJIREEICE meets the suggestive parameters outlined in the latest University Grants Commission (UGC) for peer-reviewed journals, ensuring high standards of research integrity, publication ethics, and academic excellence.
← Back to VOLUME 4, ISSUE 10, OCTOBER 2016

Comparison of PD Activity in Cylindrical and Cubical Void using Matlab Simulink

C. Sunil Kumar, Dr. B. Ramachandra, Madhushree H N

πŸ‘ 1 viewπŸ“₯ 0 downloads
Share: 𝕏 f in ✈ βœ‰
Abstract: Insulators plays an important role in high voltage power equipments as they protect the equipments and ensure their reliable operation. The insulator has certain impurities in it such as voids and cracks as no insulator can be completely free from impurities. The insulator when subjected to high voltage degrades in terms of its performance due to the imperfections present in it such as voids. It is linked to occurrence of partial discharge. Partial discharge is nothing but localized electrical discharge that only partially bridges the insulation between conductors and which may or may not occur adjacent to a conductor [1]. It indicates the presence of an imperfection within the insulation. The magnitude of these discharges though small, can cause progressive deterioration and ultimate failure. Considerable efforts have been made so as to analyze PD pulse patterns, PD pattern recognition and charge transfer [5]. Thus while diagnosing insulator for its desired performance partial discharge is an important phenomenon that has to be considered. In this work an electric circuit model of an epoxy resin with void of cylindrical and cubical shape is considered for realization of partial discharge activity inside the insulator with the application of high voltage using MATLAB Simulink environment. The results obtained with cylindrical and cubical void as an impurity is compared and analysed.

Keywords: Partial discharge (PD), void, High voltage (HV), Ca, Cb and Cc.

How to Cite:

[1] C. Sunil Kumar, Dr. B. Ramachandra, Madhushree H N, β€œComparison of PD Activity in Cylindrical and Cubical Void using Matlab Simulink,” International Journal of Innovative Research in Electrical, Electronics, Instrumentation and Control Engineering (IJIREEICE), DOI: 10.17148/IJIREEICE.2016.41007

Creative Commons License This work is licensed under a Creative Commons Attribution 4.0 International License.